Wiring Guide


Programming Guide

Installer Programming Code
 *2525# (default)


Change Installer Programming Code
Press [0] + [New Installer Password 3-6 digits] + [#] + [Confirm New Installer Code] + [#]
Press [*] to exit from programming mode.

Add RFID Card With Index Code
Press [1] + [Index Code 001-200] + [#]
Scan continuously it will auto continue register the unused index code.
Press [*] when done to exit from programming mode.

Add RFID Card Without Index Code
Press [2] and scan card continuously max to 200 card.
Press [*] to exit from programming mode.

REMARK: It will automatically look for available index code to store a new card without deleting any stored card.

Add/Change RFID Card Pin Code
Press [3] follow by Scan Card + [New Password 3-6 digit] + [#] + [Confirm New Password] + [#] + Repeat for another card.
Or
Press [3] + [Index Code] + [#] + [New Password 3-6 Digit] + [#] + [Confirm New Password] + [#] Repeat for another card.
Press [*] to exit from programming mode.

Assign A Pin Code To All Cards
Press [4] + [Password 3-6 Digit] + [#] + [Confirm Password] + [#]
Press [*] to exit from programming mode.

Delete A Card(s) By Index Code/Scan
Press [5] followed by index code
+ [Index Code 1] + [#]
+ [Index Code 2] + [#]
And continuously using the same steps.
Or
Press [5] followed by scan card
+ [Scan Card 1] + [#]
+ [Scan Card 2] + [#]
Press [*] to exit from programming mode.

Delete Memory
Press [6] + [1] Wait for 2 beeps
Remark: Delete all card and pin codes (Reprogram)
or
Press [6] + [2] Wait for 2 beeps
Remark: Delete all pin codes

Change Lock Release Time
Press [7] + [Time 006-200 sec max]